Gate Titan // Aster mag cutout fix
Install sup53p06 second art mosfet across -ive mag terminal along with flyback diode and RCD snubber in the mags to eliminate motor EMF
It's not pretty, apologies wiring diagram to follow.
Parts required:
1 x Sup53P06 Mosfet
2 x 1N4007 Diode
1 x TS14 16V 470uf Capacitor
1 x 100 Ohm 0.5W Resistor
Thanks to sythe for suggesting sup53p06 as a readily locally available switching circuit
As always feel free to swing me a like and or follow me on Facebook at https://www.facebook.com/Nordic.AEG